Commercial water filtration systems for restaurants, car washes, hotels, breweries, labs and light industry: commercial reverse osmosis from 500 to 50,000 GPD, 2″ Clack WS2 backwashing filters with your choice of media, commercial UV disinfection and commercial water softeners. Every system is built to order and quoted to your water test and flow. How to put a commercial treatment train together is below the products.
Commercial water treatment is rarely one box. It's a short train of equipment, each stage solving one problem, sized to the building's peak flow in gallons per minute and, for RO, its daily gallons. Start with a water test and a flow number; the table below maps the common problems to the stage that fixes them, and our team will size and quote the full train from your report.
| Water problem | Treatment stage | Systems |
|---|---|---|
| Hardness — scale on boilers, dish machines, fixtures | Ion-exchange softener | Commercial water softeners — Clack WS 1.5 / WS2 EE, Fleck 2815 / 2900 / 9500, 35–205 GPM |
| High TDS — spot-free rinse, boiler feed, beverage, lab, process water | Reverse osmosis | Crystal Quest Mid-Flow RO (500–7,000 GPD) · Crystal Quest High-Flow RO (10,000–50,000 GPD) |
| Iron, manganese, sediment, chlorine, low pH, turbidity | Backwashing media filter | Clack WS2 Commercial Filtration System — 2″ valve, 18×65″ to 30×72″ tanks, seven media options, up to 75 GPM |
| Bacteria, viruses, coliform — well-supplied businesses, food and beverage | UV disinfection | Commercial UV systems — VIQUA VP600 / VP950 / H+ / PRO50, 24–50 GPM |
Commercial RO systems are rated in gallons per day (GPD) of permeate at a standard feed pressure and temperature; real output drops on cold, high-TDS feed water, so size with 25–30% headroom. Most systems run into an atmospheric storage tank with a repressurization pump rather than feeding fixtures directly, which lets a smaller RO run continuously instead of a large RO running in bursts. Hard feed water should be softened first — hardness is the fastest way to scale an RO membrane.
| Daily RO demand | System | Typical use |
|---|---|---|
| 500–1,800 GPD | Mid-Flow RO, 500 / 750 / 1,000 / 1,500 / 1,800 GPD, optional 165–550 gal storage kit | Restaurants and coffee shops, small labs, dental and medical offices, single-bay spot-free rinse |
| 2,500–7,000 GPD | Mid-Flow RO, 2,500 / 4,000 / 5,000 / 7,000 GPD | Car washes, breweries, greenhouses, humidification, boiler make-up |
| 10,000–50,000 GPD | High-Flow RO, 10K / 15K / 20K / 30K / 40K / 50K GPD | Bottling, food processing, industrial rinse and process water, multi-bay car washes |
The Clack WS2 Commercial Filtration System is a 2″ Clack WS2 EE valve on a fiberglass tank you specify by media, so the same hardware handles most non-hardness problems. Service and backwash flow depend on tank size and media — the PDP has the full flow table.
| Media | Removes | Notes |
|---|---|---|
| Katalox Light | Iron, manganese, some hydrogen sulfide | Highest capacity iron media; long life |
| Greensand Plus | Iron, manganese | Proven on variable well water; regenerate with air or chlorine |
| Birm | Clear-water iron | Lowest cost; needs pH 6.8+ and dissolved oxygen |
| Jacobi activated carbon | Chlorine, chloramine, taste, odor, organics | Protects RO membranes and softener resin downstream |
| Calcite / Corosex | Low pH (acidic water) | Raises pH to stop copper and lead leaching from plumbing |
| Filter Ag Plus | Sediment, turbidity to ~5 micron | High flow, low backwash; first stage on dirty surface or well water |
| Turbidex | Fine sediment, turbidity to ~3 micron | Finer than Filter Ag; higher backwash rate |
| Business | Typical treatment train |
|---|---|
| Restaurant / café | Carbon filter → softener for dish machine and steamers → 500–1,000 GPD RO for espresso, ice and beverage lines |
| Car wash | Sediment filter → twin-alternating softener → 2,500–7,000 GPD RO with storage tank for spot-free rinse |
| Brewery / beverage | Carbon (dechlorination) → RO sized to batch volume → blend back minerals to target profile |
| Hotel / multifamily | Twin-alternating softener → carbon filter; UV if on a private well |
| Well-supplied business (farm store, school, campground) | Sediment → iron filter (Katalox or Greensand) → softener → UV disinfection |
| Manufacturing / boiler plant | Filtration → duplex softener → RO for boiler make-up or process rinse |
Commercial systems ship by LTL freight on a pallet, curbside, with liftgate service included at no extra charge — no forklift required. Systems are built to order, so ask for the current lead time when you request a quote. Call 800-374-2143 to talk through your application, or request a custom quote with your water test and flow requirements.